Sysmex XN-L Series

As the global leaders in hematology, we consider it our responsibility to offer you solutions that make your work easier, more efficient and more effective. In 2011 we introduced the benchmark in hematology – our flagship XN-Series. For some, such a comprehensive solution may be too large. Now, with the introduction of the XN-L Series, XN quality and Sysmex’s knowledge and support are within your grasp.

Whether you want to upgrade from a 3-part differential device or replace an existing analyzer, all XN-L models are full 5-part differential analyzers that offer the quality

of larger devices at an excellent price: quality ratio.

The new XN-L Series comes in three models: the XN-350, the XN-450 and the XN-550. Each is also a perfect secondary analyzer, giving you confidence even at times when your primary analyzer is unavailable

Sysmex XN 350

Dimensions/weights

W x H x D [mm/kg]

XN-350: 450 x 510 x 460 / approx. 35 kg
Throughput up to 60 samples/h in WB mode

up to 70 samples/h in WB mode with the optional Speed-up license

Aspiration volume 25 µL in WB mode,

70 µL in PD and BF mode

Analysis parameters Whole Blood

WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT#, LYMPH#, MONO#, EO#, BASO#, NEUT%, LYMPH%, MONO%, EO%, BASO%, IG#, IG%

With RET (optional)

RET#, RET%, IRF, LFR, MFR, HFR, RET-He, PLT-O

Body Fluids with XN-BF (optional)

WBC-BF, RBC-BF, MN#, PMN#, MN%, PMN%, TC-BF#

Measurement principles WBC DIFF/RET: Fluorescence Flow Cytometry

WBC: Flow Cytometry

RBC/PLT: DC Impedance method with hydrodynamic

focussing

HGB: Cyanide-free SLS method

Data storage capacities Results: 100,000 samples

Patient information: 10,000 records

Calibration history: 20 times/ module

QC files: 99 files including XbarM

User Maintenance     Daily shutdown

Weekly cleaning sequence with Cellclean or Cellclean Auto

 

Sysmex XN-450

Dimensions/weights

W x H x D [mm/kg]

XN-450: 450 x 440 x 460 / approx. 35 kg
Throughput up to 60 samples/h in WB mode

up to 70 samples/h in WB mode with the optional Speed-up license

Aspiration volume 25 µL in WB mode,

70 µL in PD and BF mode

Analysis parameters Whole Blood

WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT#, LYMPH#, MONO#, EO#, BASO#, NEUT%, LYMPH%, MONO%, EO%, BASO%, IG#, IG%

With RET (optional)

RET#, RET%, IRF, LFR, MFR, HFR, RET-He, PLT-O

Body Fluids with XN-BF (optional)

WBC-BF, RBC-BF, MN#, PMN#, MN%, PMN%, TC-BF#

Measurement principles  WBC DIFF/RET: Fluorescence Flow Cytometry

WBC: Flow Cytometry

RBC/PLT: DC Impedance method with hydrodynamic

focussing

HGB: Cyanide-free SLS method

Data storage capacities Results: 100,000 samples

Patient information: 10,000 records

Calibration history: 20 times/ module

QC files: 99 files including XbarM

User Maintenance     Daily shutdown

Weekly cleaning sequence with Cellclean or Cellclean Auto

 

Sysmex XN-450

Dimensions / weights

W x H x D [mm/kg]

XN-550: 450 x 450 x 660 / approx. 53 kg
Throughput up to 60 samples/h in WB mode

up to 70 samples/h in WB mode with the optional Speed-up license

Aspiration volume 25 µL in WB mode,

70 µL in PD and BF mode

Analysis parameters Whole Blood

WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT#, LYMPH#, MONO#, EO#, BASO#, NEUT%, LYMPH%, MONO%, EO%, BASO%, IG#, IG%

With RET (optional)

RET#, RET%, IRF, LFR, MFR, HFR, RET-He, PLT-O

Body Fluids with XN-BF (optional)

WBC-BF, RBC-BF, MN#, PMN#, MN%, PMN%, TC-BF#

Measurement principles  WBC DIFF/RET: Fluorescence Flow Cytometry

WBC: Flow Cytometry

RBC/PLT: DC Impedance method with hydrodynamic

focussing

HGB: Cyanide-free SLS method

Data storage capacities Results: 100,000 samples

Patient information: 10,000 records

Calibration history: 20 times/ module

QC files: 99 files including XbarM

User Maintenance Daily shutdown

Weekly cleaning sequence with Cellclean or Cellclean Auto