Meet ever-increasing pressures on time and productivity with ease. The AU680 clinical chemistry analyzer gives mid- to high-volume laboratories the flexibility to improve efficiencies and economics their way. Operate the AU680 as a standalone system or connect it to laboratory automation and IT solutions. With a throughput of up to 800 photometric tests per hour (up to 1,200 with ISEs) and 63 onboard parameters, the AU680 clinical chemistry analyzer delivers field-proven reliability and efficiency to laboratories around the world
Analytical System | Fully automated, random-access clinical chemistry system with STAT capability |
Analytical Principles | Spectrophotometry and potentiometry |
Analytical Types | Endpoint, rate, fixed point and indirect ISE |
Analytical Methods | Colorimetry, turbidimetry, latex agglutination, homogeneous EIA, indirect ISE |
Simultaneously Processed Analytes | 60 photometric tests + 3 ISE |
Throughput | 800 photometric tests/hour; up to 1,200 with ISE |
Sample Types | Serum, plasma, urine, whole blood (HbA1c) and other fluids |
Sample Feeder | Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 150 samples; continuous loading |
Sample Tubes | In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm |
STAT Samples | Up to 22 positions for STAT samples, barcoded primary tubes |
Sample Volume | 1–25 ?L in 0.1 ?L increments (1–25 ?L for repeats) |
Reagent Supply | 60 positions for R1, 48 positions for R2; refrigerated: 4–12°C; handling of 3-shot reagents |
Reagent Volume | R1: 15–250 ?L; R2: 15–250 ?L; in 1 ?L increments |
Total Reaction Volume | 120–425 ?L |
Reaction Cuvette | Quartz cuvettes |
Reaction Time | Up to 8 minutes, 40 seconds |
Reaction Temperature | 37°C |
Mixing Method | With rotating paddles after dispensing sample and reagent |
Photometry System | Direct assay through the reaction cuvette (0–3.0 OD) mono and bichromatic measurements possible |
Wavelength | 13 different wavelengths between 340–800 nm |
Cuvette Cleaning | Comprehensive cleaning with detergents |
Calibration | Autocalibration, cooled calibrator positions; master calibration established by two-dimensional barcode on the reagent bottle (>3-point calibration) |
Quality Control | Auto QC, cooled QC positions |
Test Requisition | Individual and profile test requisition via online, mouse, function keys or touch screen |
Safety | Clot detection and crash prevention for sample and reagent dispenser |
Online | Full uni- and bi-directional communication possible |
Software | Windows 7® |
Data Storage | Sample number: 100,000 samples. Reaction data: 200,000 tests. |
Dimensions (WxHxD) | ANL 1,950×1,280×1,000 |
Power Supply | 200 V; 208 V; 220 V; 230 V; 240 V; 50 Hz; 60 Hz/3.8 KVA |