Clinical Automated & Manual Elisa Processors

DYNEX DSX

Description

The DYNEX DSX® is the next stage of our fully automated 4-plate ELISA processing system. This breakthrough technology has transformed labs and medical facilities across the country with its state of the art design, seamless automation and intuitive interface.

DSX® is a tried-and-tested automated open system capable of performing several assays per plate simultaneously, providing optimized efficiency and speed. The system uses a perfectly synchronized system to eliminate plate drift and ensure premium consistency across four different plate incubators. As a result, you can count on reliable quality while reaching peak performance speeds that once seemed unattainable.

The bar has been raised. Busy clinical and medium-throughput private and industrial labs require advanced automation that can handle virtually every ELISA immunoassay, all in a reliable, cost-effective package. Look no further than the DSX®.

4 independent plate incubators help manage testing workload with reduce labor, walk-away capability to maximize lab personnel efficiency.

The Worklist Load Wizard walks you through the process of setting up the DSX® worklist, graphically showing where to place reagents, samples, and places at the beginning of each run.

The DSX® delivers everything needed to ensure the rigorous, repeatable analyses required in critical applications including immunology, infectious disease, hormone, allergy, blood-chemistry, drugs-of-abuse testing, food safety, forensics and environmental testing.

For the past two years DYNEX DSX® has achieved 98.2% uptime when mean time between failure target is set at 250 days.

With over 3,500 DYNEX DSX® systems installed worldwide, DYNEX DSX® has been cited recently in 38 scientific journal publications for studies in blood borne pathogens, Quantiferon Gold Plus, autoimmune, sexually transmitted diseases, tick-borne diseases and others.

 

Dimensions Metric
Width: 106 cm
Depth: 91 cm
Height: 80 cm
Footprint: 0.98 sq m
Bench Weight: 136 kg (max.)
Ship Weight: 244 kg (max.)
Physical Specifications
Voltage: 100 – 240 V automatic conversion
Frequency: 50/60 Hz
Power Consumption: < 800 VA (online UPS recommended)
Power Supply Requirements
Photometric Range: 0.000 – 3.000 OD
Spectral Range: 405 nm – 690 nm
Filter Slots: 6 wavelength
Precision: ± 0.010 OD at 0.000 – 0.500 OD
< 1% CV at 0.501 – 2.000 OD
< 1.5% at 2.001 – 2.500 OD
Accuracy: ± 0.01 OD or 2.5%
(0.000 – 3.000 OD) whichever is greater
Read Time: < 10 seconds, single wavelength
< 20 seconds, dual wavelength
Reader Specifications
Manifold Configuration: 8-way
Programmable Volumes: 50 µL – 999 µL
Wash Buffer Capacity: 4 wash bottles at 2.0 L, with level-sensing
Residual Wash Volume: < 3 ?L per well with a dual-axis sweep in a
at-bottom plate
Dispense Precision: ? 5% CV (with 300 ?L in a 96-well plate)
Waste Container: 8 L with waste full sensor
Washer Specifications
Number of Plates: 4
Sample Capacity: 96 (98 positions available)
Continuous Sample Loading: Yes
Sample Tube Size: 10 mm – 16 mm diameter
40 mm – 100 mm height
Number of Reagents: Up to 24 (25 mL tubes)
Number of
Standard/Control Bottles: 33 (1.5 mL vials)
Assays per Plate: 1 assay per strip or up to 12 assays per plate
Dilution Wells Capacity: Up to 192 deep-well strips (24 x 8)
Sample Tip Capacity: 432 (4 x 108)
Reagent Tip Capacity: 41 tips
System Specifications
Sample Tip Size: 300 ?L
Sample Pipetting Volume: 10 ?L – 250 ?L single-shot
25 ?L – 100 ?L multi-shot
Sample Pipetting Precision: ? 3% CV at any operating volume above
10 ?L (single-shot mode)
Sample Pipetting Accuracy: ± 2% of target volume at any operating
volume above 10 ?L (single-shot mode)
Estimated Cycle Time for Sample
Pickup to Delivery on Plate: < 8 seconds^
Time to Dispense: 19 minutes (typical)^
50 ?L of 96 samples to plate from sample
tubes or deep-well plates
Sampling Time w/Dilutions: < 26 minutes (typical)^
Dilution Range: 1 part in 190 one-stage dilution
1 part in 36,100 two-stage dilution
Sample Pipetting Specications
Liquid Level Sensing: Yes (reagents, controls and samples)
Level Sensor System: Pressure dierential
Clot Detection: Yes
Dispense Anomaly Detection: Yes
Tip Detection: Yes
Electronic Signature Pipetting: Yes
Alarms: Yes
Process Security
Controlling Software: REVELATION DSX®
Work Protocols (Assays): Unlimited
Data Processing: Quantitative and qualitative
Levey-Jennings: Yes
Westgard Rules: Yes
Process Reporting: Event log + error log
Automatic Error Recovery: Yes
Password Access Control: Yes
Software
Reagent Tip Size: 1,300 µL
Reagent Pipetting Volume: 25 ?L – 1,000 µL
Reagent Pipetting Precision: ? 3% CV at 10 shots at any volume in
the operating range above 50 µL
Reagent Pipetting Accuracy: ± 2% of target volume at 50 µL or greater
in operating range (single-shot mode)
Reagent Pipetting Specications
Number of Incubators: Up to 4
Temperature Range: RT + 7° C to 50° C (elevated incubator)
RT + 5° C (ambient incubator)
Temperature Accuracy: ± 1° C
Shaking: > 15 Hz periodic or continuous
Temperature Monitoring: Yes

Tel: 281-747-6115

Address: 5850 San Felipe Suite 500 Houston, TX 77057

Follow & Subscribe