DYNEX DS2
Description
The DYNEX DS2® system is one of a kind – dynamic, precise and cost-effective processing systems. This breakthrough 2-plate ELISA processing system guarantees to change the game for laboratories looking to streamline their processes and save valuable resources. If you’re a time-strapped facility with high demands, the DS2® is the solution you’re searching for. Designed to cut costs, save labor and enhance your speed, the DS2® never compromises when it comes to unbeatable quality control.
- Fully automated open system
- Ability to bring in tests that are currently being sent out
- Automated sample distribution, incubation, reagent addition, washing and detection steps of assays as defined by the manufacturer. The lab can customize assay parameters, assay steps, OD read settings, result calculations, quality control checks and report formats with ease
- Automation, accuracy, immediacy and responsiveness are the must-haves of demanding physicians office labs and lower-throughput labs.
- Finding all this in a reliable, cost-effective and easy to use and maintain package might seem impossible. Not with the DS2
Dimensions Metric
Width: 54 cm
Depth: 68 cm
Height: 66 cm
Footprint: 0.36 sq m
Bench Weight: 48 kg
Ship Weight: 78 kg
Noise: Noise output < 78 dB
Physical Specifcations
Voltage: 100 – 240 V automatic conversion
Frequency: 50/60 Hz
Power Consumption: < 300 VA
Power Supply Requirements
Photometric Range: 0.100 – 3.0 OD
Spectral Range: 405 nm – 690 nm
Filter Slots: 6 wavelength
Precision: < 1% CV (< 2.0 OD)
< 2% CV (2.0 – 3.0 OD)
Accuracy: ± 0.005 OD or 2.5%
(0.000 – 3.000 OD) whichever is greater
Read Time: < 30 sec (single wavelength)
Reader Specications
Manifold Confguration: 8-way
Programmable Volumes: 50 µL – 1,000 µL
Wash Bufer Capacity: 2 wash bottles at 2 L, with level-sensing
Residual Wash Volume: < 3 µL with super sweep
Dispense Precision: ? 5% CV (with 300 ?L in a 96-well plate)
Waste Container: 1 x 1.5 L
Washer Specifications
Number of Plates: 2
Sample Capacity: 100 per load
Continuous Sample Loading: Yes
Sample Tube Size: 10 mm – 16 mm diameter
40 mm – 100 mm height
Number of Reagents: Up to 8 (25 mL tubes)
Up to 10 (15 mL tubes)
Number of
Standard/Control Bottles: 24 (2 mL vials)
Assays per Plate: Up to 12
Dilution Wells Capacity: Up to 96 deep-well strips (12 x 8)
Sample Tip Capacity: 216 tips (2 x 108)
Reagent Tip Capacity: 20 tips
Sample Tip Size: 300 ?L
Sample Pipetting Volume: 10 ?L – 250 ?L
Sample Pipetting Precision: < 3% CV at any operating volume above
10 uL (single-shot mode)
Dilution Range: 1 part in 199 one-stage dilution
1 part in 39,601 two-stage dilution
Sample Pipetting Specifications
Liquid Level Sensing: Yes (reagents, controls and samples)
Level Sensor System: Pressure differential
Clot Detection: Yes
Dispense Anomaly Detection: Yes
Tip Detection: Yes
Electronic Signature Pipetting: Yes
Alarms: Yes
Process Security
Controlling Software: DS-Matrix®
Work Protocols (Assays): Unlimited
Data Processing: Quantitative and qualitative
Levey-Jennings: Yes
Westgard Rules: Yes
Process Reporting: Event log + error log
Automatic Error Recovery: Yes
Password Access Control: Yes
Software
Reagent Tip Size: 1,300 µL
Reagent Pipetting Volume: 20 ?L – 1,000 ?L
Precision, Reagent Tip: < 3% CV at any operating volume above
20 uL (single-shot mode)
Reagent Pipetting Specifications
Attributes and specifications are subject to change without notice.
Number of Incubators: 2
Temperature Range: Ambient + 4° C to 40° C
Temperature Accuracy: ± 1° C across plate @ 37° C
Shaking: Independent linear motion
14 – 20 Hz (periodic or continuous)
Temperature Monitoring: Yes